Preventive Maintenance Program - BIESSE Edge

ServiceCost
Flat rate for 2 days (includes 16 labor hours)$1000.00 (per visit)
Any day after the 2nd day$600.00 (per visit)
Additional CostCost
Meals$35.00/day
Travel hoursActual (per visit)
Expenses (Airfare, car, lodging, etc.)Actual (per visit)

This will include a general tune-up the machine, making sure everything is working well, and recommending any parts to be changed (see checklist below).

It will not include any repair/additional training on the machine not listed in the checklist. If repair/additional training is necessary it will require a different purchase order from the customer and the regular rates will apply.

It is Biesse Group America’s discretion (depending on the technician’s schedule and on the spare parts availability) to decide if the repairs can be done at the same time of the preventive maintenance.

The program includes two (2) visits per year. The customer and Biesse Group America will come to an agreement on what time of the year is best for both to schedule preventive maintenance. BIESSE AMERICA reserves the right to schedule the visit within 14 days of the customer’s request.

Once the schedule has been established, Biesse will contact you a month before so that we can schedule a PM maintenance.

Below is a list of items that will be checked on your BIESSE STREAM
  • Machine & outrigger support level
  • Calibration of pressure rollers / band and pressure beams
  • Calibration of end trimming unit
  • Calibration beveling units
  • Calibration of profile and flat scrapers
  • Calibration of oscillating buffing unit and condition of pads
  • Check condition of feeding track pads and guidance system
  • Tightness of all mounting hardware for units and motors
  • Limit switches and sensors: position and tightness
  • Encoder mounting elements
  • Gluepot condition
  • Glue roller lubrication / alignment
  • Glue pre-melter
  • Tape feed magazine
  • End trim blades and all cutter inserts
  • Setting of all air pressure regulators
  • Inspection of all safety interlocks and advise customer of any "by-pass" situation
  • Main air lubricator (one drop every twenty cycles)
  • Make backup copy of all parameters in NC410D
  • Setting alarm set point on both thermo regulators
  • Condition of heating elements and thermocouples

  © Copyright 2008 Biesse America